Siemens softwareSimcenter FloMaster
Siemens Digital Industries Software · Simcenter

Simcenter FloMaster

Built for piping networks: hundreds of branches, valves, pumps and heat exchangers solved simultaneously, which single-device simulation cannot achieve.

Whole network
hundreds of branches at once
Water hammer
surge on valve closure
Balancing
flow between branches
VN
local engineering support

Typical problems

Flow balancing

Which branch gets enough flow and which is starved — the classic problem of water, steam and compressed air distribution in a plant.

Water hammer

A sudden valve closure or a pump power loss creates a pressure surge large enough to break the pipe. FloMaster computes the surge amplitude and where the danger is.

Pipe and pump sizing

Diameters and pump ratings selected from a whole-system calculation.

Applications

  • Plant water and steam systems — distribution, return, branch balancing
  • Fuel and compressed air systems — pressure loss, compressor selection
  • Transients — pump start-up, valve opening and closing, power failure
  • Heat exchanger networks — temperature along the route and pipe heat losses
A piping network diagram in Simcenter FloMaster
/image/phan-mem/flomaster.jpg3:1 ratio (banner)
The whole network solved at once instead of section-by-section loss calculations by hand.

Coupled tools

Simcenter STAR-CCM+

Loss coefficients for complex components taken from 3D simulation into the network.

View details →

Simcenter Amesim

For systems that also include controls and mechatronics beyond the fluid side.

View details →

Simcenter FloEFD

Detailed assessment of a single valve or fitting inside the network.

View details →

Applications at CFDWAYS

  • Checking a piping network design before construction
  • Identifying why a branch is starved of flow in an operating plant
  • Assessing water hammer risk when the operating regime changes

Industries served

Licensing & support

FloMaster is licensed by platform plus component libraries. For an organization that only needs one specific system checked, CFDWAYS can provide the analysis as a service instead of selling a license.

Indicative system requirements

Operating systemWindows 10/11 64-bit
CPU / RAMA mid-range office PC is sufficient
Data requiredP&ID diagrams, pump curves, fitting loss coefficients

Frequently asked questions

How is it different from calculating losses in a spreadsheet?

A spreadsheet handles a simple route. Once the network has closed loops, many parallel branches or transients, the whole network must be solved simultaneously in FloMaster.

What data is needed to start?

P&ID diagrams, pipe lengths and diameters, pump and valve characteristics. Without the component characteristics the results only show trends.

Is one branch of your piping network starved of flow?

Send the P&ID and operating parameters — CFDWAYS will make a preliminary assessment of the cause.

Send project details

See more: The full Siemens software portfolio · Simcenter Amesim · Energy, oil & gas industry